TNF507 Fundus Camera
TNF507 fundus camera integrates with fundus fluorescein angiography, fudund color photography and non-mydriatic fundus photograph functions through the combination of different filter system.
It not only meets the need of the daily outpatient in ophthalmology, but also is a powerful instrument of fundus screening. High pixel resolution, SLR imaging system, excellent optical system, efficient and high-quality fundus imaging solutions etc. offering the clinical fundus imanges as needed, significantly contributes to clinical medicine development.
Top-level pixel resolution offer clients incomparable experience in detail.
TNF507 fundus camera offers 18.0 megapixels image with outstanding optical system. Part of the photo will be ultimate clear as before after magnified, which is vital to minimal lesion.
External SLR imaging system get the clients acquiring clear photos easily.
TNF507 fundus camera adopt external SLR imaging system, which not only provide accurate color and wealthy details, but also upgrade the instrument will be more easier.
High pixel imaging offer the incomparable radiography in detail.
TNF507 fundus camera can also offer high quality fundus angiography image under the operation mode of the fluorescence imaging. It is also visible although the blood vessel is extremely subtle. And the dark light greatly increase the comfort and fitness of clients. Clear photos can be gained easily.
Combine the function of mydriatic fundus photography and non-mydriatic fundus photography.
TNF507 fundus camera have the function both of mydriatic fundus photographyand and non-mydriatic fundus photography. That totally satisfie the need of professional ophtalmic testing and retinal screening.
The interface is very brief and easy to use.
TNF507 fundus camera has simple appearance and abundant assisted imaging system. The person who never use the equipment can also easy to use because of double dot auxiliary focusing system.
Low flash shooting mode.
TNF507 fundus camera can also capture clear and bright picture on the condition of low flash shooting mode, which greatly increase the comfort of clients.
|
Types of photography
|
Color,non-mydriatic color,FFA, Red Free
|
|
Angle of view
|
50 ° max
|
|
Working distance
| 42mm
|
|
Retinal observation
| LCD
|
|
Minimum pupil size
|
Mydriatic: 5.1 mm or more Non-Mydriatic: 3.5 mm or more
|
|
Imaging device
|
DSLR
|
|
Sensor
|
18.0 Megapixels
|
|
Fixation target
| LED
|
| Diopter compensation
|
±20D
|
| Focusing mode
| Double dot auxiliary focusing
|
| Display mode
| Double-screen display
|
Adjustments
|
|
Base movement
|
80mm front and back, 100 mm side to side
|
|
Panning range
|
30 degrees to the right and left
|
|
Tilting range
|
15 degrees up, 10 degrees down
|
Electrical and Environmental
|
|
Power supply
|
AC 220V 50/60 Hz
|
|
Operating environment
|
Temperature: 10°C to 35°C Humidity: 30% RH to 80% RH
|